Cat 1 vs. Cat 5 Elevator Testing: A Plain-English Guide for NYC Property Managers
What Category 1 and Category 5 elevator tests are, how they differ, why NYC requires an independent witness, and how to prepare your building.
If you manage a building in New York City, “Cat 1” and “Cat 5” come up every year. This guide explains what the two periodic tests are, how they differ, and how to plan for them. It is general information, not legal advice. The NYC Department of Buildings (DOB) sets the rules, deadlines, and fees, and they can change, so check current DOB guidance before acting.
What is a Category 1 (Cat 1) test?
A Category 1 test is the no-load test, commonly done once a year. A mechanic checks the elevator’s safety devices and related systems using code-defined procedures, without putting rated load on the car.
In practice, Cat 1 is the regular safety check that confirms the main protective systems still work as designed.
What is a Category 5 (Cat 5) test?
A Category 5 test is the full-load test on a longer cycle, commonly described as every five years. It is more involved than Cat 1. Depending on the equipment and procedure, it can mean testing safeties and buffers with rated load, which often requires test weights and more time with the car out of service.
Because it is more intensive, Cat 5 usually takes more planning: scheduling downtime, telling residents or tenants, and lining up labor and equipment.
Side-by-side
| Category 1 | Category 5 | |
|---|---|---|
| Load condition | No load | Full / rated load |
| Typical cadence | Commonly annual | Commonly every five years |
| Downtime | Usually shorter | Usually longer |
| Planning effort | Moderate | Higher (weights, scheduling) |
Cadence shown is the common description. Confirm the exact requirement for your equipment with DOB.
NYC requires an independent witness
In New York City, Category tests must be witnessed by an independent, City-approved agency. The company doing the test does not count as the witness. Owners should plan for two parties:
- The elevator contractor who performs the test (for example, Faraday Elevator).
- The approved witnessing agency that observes it independently.
DOB keeps the current information on approved agencies and filing. Confirm it there, because approvals and procedures can change.
How to prepare your building
- Know your equipment. Have a list of every device (elevators and other conveying equipment) with its location and type.
- Book early. Both the contractor and the witnessing agency have to be available, and Cat 5 days take more coordination.
- Tell occupants. Post notices about expected downtime, especially in buildings where some residents depend on the elevator.
- Review last year’s findings. Open deficiencies from earlier inspections should be fixed or tracked.
- Plan for corrections. Tests can turn up problems that need adjustment or repair. Leave room in the schedule and budget.
What happens if a test turns up problems?
Deficiencies are normal on older equipment. What matters is that each one is written down clearly and fixed. A good contractor explains what failed, what the repair involves, and what is needed to close the item out.
Where Faraday fits
Faraday Elevator performs full Category 1 and Category 5 testing, inspections, and compliance reporting under local, state, and national codes. We work with building owners, inspectors, and management teams to meet ASME, DOB, and other applicable requirements. Testing is one part of our elevator testing services. We also provide maintenance, repair, and modernization in New York and New Jersey.
Not sure what your current contract covers for testing? Our free contract review can point out missed testing or modernization credits.
This article is general information. Elevator testing requirements, deadlines, and fees are set by the authorities having jurisdiction. Check current requirements with the NYC Department of Buildings or your local authority.
This is not legal advice. Please speak with an attorney to discuss your specific situation and how the law applies to you.